Recall Z-2468-2010 ยท ING Elevator, Wheelchair, Portable
The Braun Corporation
Braun wheelchair lift, model NCL, Braun Corporation, Winamac, IN A wheelchair lift for motor vehicles.
| Date | Sep 22, 2010 (initiated Aug 15, 2007) |
| Status | Terminated |
| Reason | The wheelchair lifts threshold warning system may not operate and the wheelchair user can fall from the vehicle and be seriously injured. |
| Root cause | Device Design |
| Action | The Braun Corporation issued a Service Bulletin 34273 entitled "Lift Threshold Sensitivity Bulletin 34273 on October 2007. Braun Corporation also sent a "Safety Recall" letter to the Braun lift owner and letters to all customers on or about August 15, 2007. The letters described the product, problem and the action to be taken by the customer. The customers were instructed to notify the National Highway Traffic Safety Administration (NHTSA) and conduct a safety recall if they used recalled lifts as original equipment in a system or vehicle that they built; ensure that any associated customers |
| Quantity | 3,066 |
| Distribution | Worldwide distribution |
| FDA record | Open on fda.gov |
510(k) clearances named in this recall
| K952946 | VANGATOR II Crow River Industries, Inc., Nov 29, 1995 |