Recall Z-0522-06 ยท INI Vehicle, Motorized 3-Wheeled
Tung Keng Enterprise Co., Ltd.
The product is a mobile 3-wheeled electric scooter, model HMV 250. The product contains either a red or blue base. The red base is identified with SKU #915363224. The blue base is identified with SKU #915363225. The product is distributed by the Invacare Corporation.
| Date | Feb 16, 2006 (initiated Nov 1, 2005) |
| Status | Terminated |
| Reason | The throttle spring, located in the hand throttle assembly, can fracture, resulting in the scooter not stopping when the user releases the throttle. |
| Root cause | Other |
| Action | The recalling firm sent field correction instructions to their customers on or about 11/1/05. |
| Quantity | 8,213 total devices |
| Distribution | The product was distributed to OHL/Invacare, Rancho Technology Park Bldg. B 8950, Rancho Cucamonga, CA 91730; OHL/Invacare, 1100 Whitaker Road, Plainfield, IN 46168; Invacare Corporation, 39400 Taylor Parkway North Ridgeville, OH 44039; and Invacare, Dallas Texas Distribution Center, 3460 South Wats |
| FDA record | Open on fda.gov |
510(k) clearances named in this recall
| K033240 | BE-MOBILE 3-WHEELED ELECTRIC SCOOTER, MODEL DK S200 Tung Keng Enterprise Co., Ltd., Dec 18, 2003 |