Recall Z-1002-2023 ยท OWB Interventional Fluoroscopic X-Ray System
Siemens Medical Solutions USA, Inc
Luminos Agile Max, Luminos dRF Max, and LUMINOS Lotus Max
| Date | Jan 20, 2023 (initiated Dec 9, 2022) |
| Status | Open, Classified |
| Reason | There is potential for the footrest to detach from the patient table during use. Device intended to visualize anatomical structures by converting an Xray pattern into a visible image. The system has medical applications ranging from gastrointestinal examinations to cranial, skeletal, thoracic and lung exposures as well as examinations of the urogenital tract. The unit may also be used in emergency applications, lymphography, endoscopy, myelography, venography, arthrography, interventional radiology, digital angiography, and digital subtraction angiography (DSA). The system may be used on pedi |
| Root cause | Process control |
| Action | A Customer Safety Advisory Notification (CSAN) was distributed to affected consignees beginning December 9, 2022. The CSAN was distributed to inform the customers about a preventative measure to exclude any potential risk of patient injury caused by the footrest detaching from the patient table during examination. Together with the CSAN, an addendum to the operator manual is distributed containing additional details and illustrations on how to securely attach the footrest to further improve the understanding of handling the footrest. Refer to the CSAN with addendum and copies of the Instructio |
| Quantity | 886 units |
| Distribution | Worldwide distribution |
| FDA record | Open on fda.gov |
510(k) clearances named in this recall
| K173639 | Luminos dRF Max, Luminos Agile Max, Uroskop Omnia Max, Multitom Rax Siemens Medi Cal Solutions, Inc., Apr 2, 2018 |