ClearanceBrief
Recall Z-2870-2017 ยท REA High-Power Laser Light Show Projector

X-Laser Llc

X-Laser Laser Light Show projector models Aurora, Caliente Aurora, PSX-400, Mobile Beat Max, Mobile Beat Max MKII, X-Beam, Hawk 500 High-power laser light show projector.

DateJul 24, 2017
StatusTerminated
ReasonFailure to comply with performance standard requirements (21 CFR 1040.10(f))when operated in the user accessible auto and music modes of operation
Root causeDevice Design
ActionX-Laser LLC will bring into compliance: 1. All purchasers and associated dealers of affected LLS projector models will be notified by mail and email of their failure to comply with the performance standard. The notification will follow the format and include the information required by 21 CFR 1003.21. Those that do not respond within 14 days will be notified a second time. Those not responding to the second attempt will be notified again every 6 months for the next 2 years. Non-responsive dealers will be ineligible for future orders. 2. All affected LLS projectors will be repaired by rem
Quantity830
DistributionUS Distribution
FDA recordOpen on fda.gov

510(k) clearances named in this recall

This recall record lists no 510(k) number.