ClearanceBrief
Recall Z-2777-2017 ยท RCE Cabinet X-Ray, Industrial

GE Inspection Technologies, LP

GE Inspection Technologies Blade|line Industrial Cabinet X-ray system

DateJun 28, 2017
StatusTerminated
ReasonGE Inspection Technologies, LP determined that the Blade|line cabinet x-ray system fails to comply with the cabinet x-ray performance standards emission limit of 0.5 milliRoentgen in one hour (21 CFR 1020.40(c)(1)(i)) underneath the bottom center of the system. The crawl space affected by the excess emission is approximately 22 inches high, normally covered by decorative panels, and is not intended to be accessed.
Root causeRadiation Control for Health and Safety Act
ActionGE Inspection Technologies will bring the defect into compliance: 1. Four panels of sheet metal/lead/sheet metal construction (6 mm lead thickness) will be permanently mounted using an industrial epoxy to the inside floor of the cabinet to prevent emissions from exceeding the limit in the performance standard. A radiation emission measurement will be made following the repairs of each system to assure the issue was corrected. 2. GE will notify affected customers within 5 days of GEs receipt of this approval letter. 3. The notification will recommend that customers allow GE to visit
Quantity13 units distributed in the US
DistributionUS Distribution to the states of : AL, SC, OH, MI, PA, and Internationally to Germany and Singapore
FDA recordOpen on fda.gov

510(k) clearances named in this recall

This recall record lists no 510(k) number.